Continuous Emission Monitoring System for Flue Gas HCl Co Waste Incineration CEMS Gas Analyzers

HCl Continuous Emission Monitoring System
,HCl CEMS Gas Analyzers
,Waste Incineration CEMS
WT Online Gas Monitoring System
1. Basic Design Principle of the WT-400 Analysis System
The WT-400 Ammonia Analysis System adopts a high-temperature extractive monitoring method, with a laser-based NH₃ analyzer as the core unit. All gas-contacting components are heated and insulated to above 180℃ throughout the sampling path, ensuring stable and accurate NH₃ measurements even under challenging process conditions.
2. Operating Conditions and Requirements
2.1 General Process Conditions
-
Maximum dust concentration: < 2000 g/Nm³
-
Flue gas temperature at the sampling point: ≤ 600℃
-
Sampling point pressure: -15 to 15 MPa
-
Tar and benzene content: < 10 g/Nm³
-
Presence of saturated water vapor
2.2 Environmental Conditions
-
Temperature control cabinet installed outdoors; analyzer unit installed indoors
-
Ambient temperature: 5–45℃
-
Relative humidity: 20–85% RH
-
Atmospheric pressure: 10–106 kPa (depending on site location)
2.3 Utilities and Gas Supply
-
Power Supply: 220V ±10%, 50Hz ±1Hz; Power consumption: 5 kVA; free from strong electrical interference
-
Compressed Air: For purging the sampling system to prevent clogging; must be clean, dry, oil-free, with a pressure of 4–7 kg/cm² to ensure effective cleaning
-
Standard Gas: For system preprocessing, calibration, and performance verification; must meet the specified purity requirements to maintain measurement accuracy
-
No. Standard Gas Compositions Standard Gas Concentration Standard Gas Pressure 1 N2 ≥ 99.9999% 0.5 -10 MPa 2 NH3 80% of the measurement rage 0.5 -10 MPa
3. Features of the WTKF200 Ammonia Escape Online Monitoring System
-
Integrated Sampling Probe – Compact, streamlined design with large dust holding capacity; supports dust filtration up to ≤ 100 g/Nm³ without clogging.
-
High Filtration Precision – Dust filtration accuracy < 0.1 μm.
-
High Measurement Accuracy – Analysis accuracy of ±1% FS.
-
Fast Response – Response time (T90) ≤ 30 s.
-
High Reliability – Mean Time Between Failures (MTBF) > 3 years.
-
Low Maintenance – Maintenance interval exceeds 1 year.
-
Distortion-Free Sampling – High-temperature extractive sampling method ensures accurate, representative measurements.
-
Temperature-Controlled Sampling – High-temperature, constant-temperature design maintains NH₃ measurement accuracy.
-
Automatic Purging – Built-in automatic cleaning system removes dust and prevents blockages.
-
Signal Output – 4–20 mA output; control alarm signal NO/NC, 1A/220V.
We offer fully customized gas online monitoring solutions tailored to the customer’s unique requirements and operating environments, ensuring optimal performance and measurement accuracy.

KF-200 in-Situ Non-Sampling Laser Gas Analyzer

High Performance Sensor KF200 Series TDLAS Laser Gas Analyzer for CO O2 NH3 CO2 CH4 H2O HC HF

Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System

KF200 In-situ Laser Gas Analyzer TDLAS For Real-Time Monitoring Of CO NH₃ HCl And O₂ In Industrial Emissions
Image | Part # | Description | |
---|---|---|---|
![]() |
KF-200 in-Situ Non-Sampling Laser Gas Analyzer |
|
|
![]() |
High Performance Sensor KF200 Series TDLAS Laser Gas Analyzer for CO O2 NH3 CO2 CH4 H2O HC HF |
TDLAS industrial on-line analyzing and online environmental monitoring
|
|
![]() |
Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System |
Continuous Emission Monitoring System for HCl and CO in Waste Incineration Flue Gas (CEMS)
|
|
![]() |
KF200 In-situ Laser Gas Analyzer TDLAS For Real-Time Monitoring Of CO NH₃ HCl And O₂ In Industrial Emissions |
The KF200 Series Laser Gas Analyzer is specifically designed for industrial online analysis and continuous environmental
|