logo
Home > products > Laser Gas Analyzer > KF-200 in-Situ Non-Sampling Laser Gas Analyzer

KF-200 in-Situ Non-Sampling Laser Gas Analyzer

manufacturer:
KELISAIKE
Category:
Laser Gas Analyzer
In-stock:
1PC
Price:
US$7,999.00 - 70,000.00
Payment Method:
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Shipping Method:
LCL, AIR, FCL, Express
Specifications
Model NO.:
KF200
Type:
Laser Gas Analyzer
Certification:
CE
Measurement Principle:
Semiconductor Laser Absorption Spectroscopy
Power Supply:
24VDC(18~36VDC)/220V AC
Explosion-Proof:
Exp Xmd Iic T5
EMC:
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4
Trademark:
KELISAIKE Or OEM
HS Code:
9027100090
Origin:
Nanjing, China
Highlight:

in-situ laser gas analyzer

,

non-sampling gas analyzer

,

KF-200 laser gas analyzer

Introduction
 

KF-200 in-Situ Non-Sampling Laser Gas Analyzer 0KF-200 in-Situ Non-Sampling Laser Gas Analyzer 1

>>>Key Features
1. In-situ probe mounting, real-time monitoring
2. Explosion-proof design,building block design, field replacement of Laser module
3. Using magnetic pen control, convenient operation

 

 

>>>Technical Features
1. Adopting the TDLAS technology, thein-situ online gas analyzing
2. Double proof probe design, without positive pressure purge, no additional data processing unit, simple compact structure, high reliability
3. Using high-power lasers, no fiber coupling, anti-harsh working conditions (such as excessive dust condition)
4. Using patented technology of spot light path adjustment, easy for on-site installation



>>>Technical Specifications

 

Measurement Principle Tunable Laser Absorption Spectroscopy(TDLAS)
Technical Data linearity error ≤±1%F.S.
Span drift ≤±1%F.S./6 months
Repeatability ≤1%F.S.
calibration period ≤1 time/6 month
Explosion-proof Grade Exp xmd IIC T5
Protection levels IP65
Response Time Warming-up time ≤15 min
Response time(T90) ≤1s
Interface Signals Analog outputs 2-wire 4-20mA signal output(Isolated, maximum load 750Ω)
Analog inputs 2-way 4-20mA input( temperature-pressure compensation)
Relay output 3-wire relay(24V,1A)
Digital Communication RS485/RS232/GPRS/Bluetooth
Laser Safety Standard GB 7247.1-2001(idt IEC 60825-1:1993)
Operating Conditions Storage temperature -40ºC~80ºC
Ambient temperature -30ºC~60ºC
EMC IEC 6100-4-2,IEC 6100-4-3,IEC 6100-4-4,IEC 6100-4-5,IEC 6100-4-11
Gas jet 0.3~0.8MPa Industrial nitrogen inlet and purification 
instrument gases etc.
Power DC 24V (DC 18~36V),AC 220V,power is base on specific configuration
Consumption <20W
Installation Method Sampling probe is mounted in the flue / pipe,system 
is installed nearby


 

 

>>>Gas Detection Limit

 

Detection gas type Detection limit Detection range
O2 0.01%Vol (0-1%)Vol., (0-100)%Vol.
CO2 10ppm (0-1000)ppm, (0-100)%Vol.
H2S 20ppm (0-2000)ppm, (0-100)%Vol.
HCl 0.1ppm (0-50)ppm, (0-100)%Vol.
NH3 0.1ppm (0-10)ppm, (0-100)%Vol.
C2H2 0.1ppm (0-10)ppm, (0-100)%Vol.
CO2 10ppm (0-1000)ppm, (0-100)%Vol.
H2O 0.3ppm (0-50)ppm, (0-100)%Vol.
HF 0.02ppm (0-5)ppm, (0-10000)ppm
HCN 0.3ppm (0-30)ppm, (0-1)%Vol.
CH4 0.4ppm (0-40)ppm, (0-100)%Vol.
C2H4 0.6ppm (0-60)ppm, (0-100)%Vol.
Remark1: The test conditions for 1m optical path, the gas pressure 1 bar, gas temperature 300k
Remark2: By increasing the optical path, proportionally lower detection limit.
 

>>>Company Information:

KF-200 in-Situ Non-Sampling Laser Gas Analyzer 2

Nanjing Kelisaike Safety Equipment Co., Ltd. founded in 2004, Nanjing Kelisaike has three subsidiaries

in Beijing, Xi'an and Xinjiang province, and over 30 domestic sales service centers.

Standard products include the K60 series portable single gas detectors, K60-IV series multi gas

detectors, K800 series fixed gas transmitters, K500 series wall-mounted gas detectors, K1000 series

gas detector control panel units, KL99 series air breathing apparatuses, etc.

Nanjing Kelisaike is also a factory with rich experience in OEM service,providing professional design

and manufacturing of customized products.

 

 

>>>Product Catalogue:

KF-200 in-Situ Non-Sampling Laser Gas Analyzer 3

 

>>>Package and Delivery:

KF-200 in-Situ Non-Sampling Laser Gas Analyzer 4

 

>>>Exhibition:

KF-200 in-Situ Non-Sampling Laser Gas Analyzer 5

 

>>> Our Services

1.For all our customers, our products have 1 year warranty, and life-long maintenance.

2.All inquiries will be replied in 24 hours.

3.Providing technical support, professional engineers are specialized in dealing with gas monitoring problems you met.

4. OEM and ODM service are welcome.

5.KELISAIKE plant is located in Nanjing, only 1 hour by high speedtrain from Shanghai. Welcome to visit the factory.

6.All products are well tested and packed before shipment; the certificate of inspection will be provided.

 

>>>Why choose KELISAIKE:

1. Mutual benefit : We are a factory. The price is much more competitive than others in the same quality.

2. Professional engineers: With 10+ years history, KELISAIKE has a professional engineering team: 4 engineers who have more

than 10 years' experience and over 5 engineer assistants in gas detection line, with Hi-Tech manufacturing equipments, we make more accurate and stable products.

3. Customize : We have strong R&D team, the custom product as your request are available.

4. Free OEM service : (a) Silk-printing your Logo(≥100PCS). (b) Design your color box(≥500PCS).

5. Mix order : We accept mix order, different model and small quantity order.

6. After service: (a) 1 Year warranty. (b) If there's any inferior-quality products are found, new ones could be sent to replace at free cost in the next order after confirmation.

 
RELATED PRODUCTS
Image Part # Description
quality [#varpname#] factory

Continuous Emission Monitoring System for Flue Gas HCl Co Waste Incineration CEMS Gas Analyzers

Continuous Emission Monitoring System for HCl and CO in Waste Incineration Flue Gas (CEMS)
quality [#varpname#] factory

High Performance Sensor KF200 Series TDLAS Laser Gas Analyzer for CO O2 NH3 CO2 CH4 H2O HC HF

TDLAS industrial on-line analyzing and online environmental monitoring
quality [#varpname#] factory

Waste Incineration Cems Flue Gas HCl Co Continuous Emission Monitoring System

Continuous Emission Monitoring System for HCl and CO in Waste Incineration Flue Gas (CEMS)
quality [#varpname#] factory

KF200 In-situ Laser Gas Analyzer TDLAS For Real-Time Monitoring Of CO NH₃ HCl And O₂ In Industrial Emissions

The KF200 Series Laser Gas Analyzer is specifically designed for industrial online analysis and continuous environmental
Send RFQ
Stock:
1PC
MOQ:
1PC