KF300 Kiln Inlet Online Gas Monitoring Accurate Emission Analysis for Cement Plant Safety & Efficiency
![quality [#varpname#] factory](http://style.portable-gasdetector.com/images/load_icon.gif)
KF300 Online Gas Monitoring Analysis System
,Kiln Inlet Online Gas Monitoring System
,Cement Plant Online Gas Monitoring Systemng
KF300 Online Gas Monitoring System
Product Description
The KF300 Kiln Inlet Online Gas Monitoring System from Kelisaike Safety is a high-performance solution designed specifically for the demanding operating conditions of cement plants. Using advanced heated extraction technology and a specialized QT100 sampling probe, it delivers accurate, real-time analysis of key gaseous pollutants such as CO₂, CO, NOx, SO₂, and O₂—directly from the kiln inlet, decomposition furnace, or preheater outlet.
Engineered for extreme environments, the KF300 operates reliably in flue gas temperatures up to 1,200 °C and dust concentrations of 2,000 g/m³, while withstanding corrosive gases such as SO₂. The pretreatment system features imported components to resist water, dust, corrosion, and clogging, ensuring continuous operation with minimal maintenance.
The integrated WT300 multi-gas infrared analyzer supports up to five gas channels with high measurement accuracy, rapid response time (<25s), and versatile data outputs including RS232/RS485 (Modbus) and 4–20 mA analog signals. Combined with the BRG100 heat-tracing sampling pipe, the system maintains sample integrity even in low ambient temperatures or humid conditions.
Automation is at the core of the KF300 design, featuring automatic sampling, purging, calibration, fault self-diagnosis, and alarm functions. This reduces manual intervention, lowers operational costs, and ensures consistent data quality for process optimization, safety assurance, and environmental compliance.
With its robust construction, intelligent control software, and industry-proven sampling technology, the KF300 is the ideal solution for cement producers seeking to improve clinker quality, reduce fuel consumption, and meet strict emission standards—all in one integrated system.
Flue Environmental Parameters
Project | Indicators |
Channel | Max 5 measured gases |
Ccnfiguration information includes | |
Measuring gas type | |
Measurement range | |
Measuring error | |
Response time | General: <25s (t90@60L/h Constant flow) |
Warm time | 3min~30minn @ambient 20℃(accord different detector configuration) |
Digital Res. (@zero
|
General: |
-0.01vol% in case of percent range(e.g. 0.001vol% for BMBT O2 channel) | |
-0.1 umol/mol in case of umol/mol range | |
Analog output | 4~20mA |
Communication | Standard RS232, RS485 with modbus protocol |
Fuse | Fuse current: 3A, Blow characteristic: Fast Acting |
Data interface | 4-way switch input; 8-way relay output |
Communication Interface | 1-way RS-232,1-way RS-485(supports Modbus protocol) |
Power | 220 V AC/50 Hz 100 W |
Image | Part # | Description | |
---|---|---|---|
![]() |
WTQY800B Continuous Emission Monitoring System For Real-time Flue Gas And Dust Measurement In Industry |
the system is designed for real-time, automatic monitoring of industrial flue gas components. It can continuously meas
|