Specifications
Type:
WT-VOC-700
Customized Support:
OEM
Output Signal:
RS-3082/485, 4~20mA
Measuring Deviation:
≤2% F.S.
Response Time:
90s (25m Heating Pipeline)
The Detection Limit:
Methane 0.1ppm
Analysis Cycle:
1.5min
Power Supply:
220VAC / 50Hz2kW (host Part, Excluding Heating Pipe, Air Compressor)
Cabinet Temperature:
(5-35) ℃
Cabinet Humidity:
(20% -90%) R
Carbinet Size:
600mm * 900mm * 2055mm
Highlight:

Professional CEMS Emissions Monitoring

,

Gas CEMS Emissions Monitoring

,

Gas CEMS Monitoring Equipment

Introduction

WT-VOC-700  Online Gas Monitoring Flue Gas Analyzer for Environmental Gas

Product Description

 The WT700A gas online monitoring system is based on GC-FID / GC-PID and other gas detection technologies and developed for real-time online monitoring of volatile organic compounds in different industries, different types of fixed sources, plant boundaries, and parks. The system uses innovative FID / PID technology to monitor VOCs gas online in real time. According to the application environment of different industries and the types and contents of pollutants discharged, the sampling, transmission, pretreatment and detection units are customized, combined and optimized .

 

Professional WT-VOC-700 CEMS Emissions Monitoring For Environmental Gas 0

 

 

Product Parameters

 

 

Project

Description

VOCs volatile organic compounds

Measuring principle

Principles of Gas Chromatography

Measuring components

Methane / Non-methane total hydrocarbons, benzene series (benzene, toluene ), etc.

Measuring range

0-1000ppm (configurable)

Propylene oxit

ethylene oxide

0-500ppm

The detection limit

Methane 0.1ppm

Repeatability

RSD≤3%

Measurement deviation

≤2% F.S.

Analysis cycle

1.5min

Response time

90s (25m heating pipeline)

Sampling pipeline

Heating temperature above 125 ℃

 

IPC

6 channels RS232/485

4 USB ports

Windows xp operating system

system software

Exhaust gas treatment ∨OC online monitoring system

Output

Analog output channel

RS485 communication interface

GPRS communication interface

Ethernet communication interface

System status switch output (optional)

Power supply

220VAC / 50Hz2kW (host part, excluding heating pipe, air compressor)

Cabinet size

600mm × 900mm × 2055mm

Cabinet temperature

(5-35) ℃

Cabinet humidity

(20% -90%) R

 

 

Company Information